F-19

TROUBLESHOOTING & REPAIR

F-19

 

 

 

 

 

NORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM

HIGH IDLE – NO LOAD

CH1

0 volts

50 volts

5 ms

This is the typical AC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 50 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

POWER-ARC 4000

Page 67
Image 67
Lincoln Electric SVM103-C service manual Normal Open Circuit Weld Voltage Waveform, High Idle no Load, Scope Settings