TROUBLESHOOTING

 

 

F-5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENTS(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

 

 

 

 

No weld output - auxiliary power

1. Check the open circuit voltage

1.

Check continuity (zero ohms) of

 

(230 - 115 VAC) operates normally -

(OCV) at the welder output termi-

 

lead W1A (black) from output

 

engine runs normally.

nals. If OCV is okay, go to Step

 

terminal to reactor (L1).

See the

 

 

 

2, below.

 

Wiring Diagram.

 

 

 

 

If OCV is not present at the welder

2.

Check continuity (zero ohms) of

 

 

 

output terminals, contact your

 

lead W2 (black) from output

 

 

 

local Lincoln Electric Authorized

 

terminal to stator winding. See

 

 

 

Field Service Facility.

 

the Wiring Diagram.

 

 

 

 

2. Check the welding cables,

3. Check continuity (zero ohms) of

 

 

 

clamps and electrode holder for

 

lead W1 (black) from reactor (L1)

 

 

 

loose or broken connections.

 

to stator winding.

See the

 

 

 

 

 

Wiring Diagram.

 

 

 

 

 

4.

Check reactor (L1) for continuity

 

 

 

 

 

of winding. See the Wiring Dia-

 

 

 

 

 

gram.

 

 

 

 

 

5.

Check the stator for continuity of

 

 

 

 

 

winding. See the Wiring Dia-

 

 

 

 

 

gram.

 

 

 

 

 

6.

Make certain the reactor and/or

 

 

 

 

 

stator are NOT grounded. Mini-

 

 

 

 

 

mum acceptable resistance to

 

 

 

 

 

ground is 500 K-ohms.

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-800-833-9353

POWER-ARC 4000

Page 53