F-20

TROUBLESHOOTING & REPAIR

F-20

 

 

 

 

 

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115 VAC SUPPLY)

HIGH IDLE – NO LOAD

1 Period = 16.2 ms @ 3700 rpm

CH1

0 volts

20 volts

5 ms

This is the typical AC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 50 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine 115 VAC receptacle.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

POWER-ARC 4000

Page 68