TROUBLESHOOTING & REPAIR | ||
|
| |
|
|
|
TYPICAL WELD OUTPUT WAVEFORM
MACHINE LOADED
CH1
0 volts
20 volts | 5 ms |
MACHINE LOADED TO 125 AMPS AT 23 VAC
This is the typical AC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 20 volts and that each horizontal division represents 5 milliseconds in time. The mahine was loaded with a resistance grid bank.
Note: Scope probes connected at machine output terminals.
SCOPE SETTINGS
Volts/Div | 20V/Div. |
Horizontal Sweep | 5 ms/Div. |
Coupling | DC |
Trigger | Internal |
|
|