TROUBLESHOOTING & REPAIR

F-6

TROUBLESHOOTING GUIDE

 

 

 

Observe Safety Guidelines

 

 

 

detailed in the beginning of this manual.

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS (Continued)

 

 

 

 

 

 

 

 

The output voltage and wire feed is

1.

Remove the gun. If the problem

1.

Check the machine's internal

present continuously

or pulsing

 

is resolved the gun trigger circuit

 

trigger leads for grounds or

when gun trigger is NOT activated.

 

is faulty. Repair or replace.

 

shorts. See Wiring Diagram.

 

 

2.

If problem persists when gun

2.

The control board may be faulty.

 

 

 

assembly is removed from

 

Replace.

 

 

 

 

machine, then the problem is

 

 

 

 

 

 

within the POWER MIG 255.

 

 

 

 

 

 

 

 

The output voltage is present contin-

Contact your local Lincoln Electric

1.

Perform the SCR

Rectifier

uously when gun trigger is NOT acti-

Authorized Field Service Facility.

 

Assembly Tests.

 

vated.

 

 

 

 

 

 

 

 

 

 

2.

The control board may be faulty.

 

 

 

 

 

Replace.

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.