Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-24

TROUBLESHOOTING & REPAIR

F-24

ACTIVE SCR RECTIFIER ASSEMBLY TEST (continued)

FIGURE F.6 — CONTROL BOARD MOLEX PLUG LOCATIONS FOR G3521 PC CONTROL BOARD.

J6

J5

J3

J8

J9

J1

J4

J2

Return to Section TOC

Return to Master TOC

TEST PROCEDURE

1.Disconnect main AC input power to the machine.

2.Remove the case top and side panels with a 3/8 in. nutdriver.

3.Remove the tool tray with a 5/16 in. nut- driver.

4.Verify that the capacitors have completely discharged with a volt- ohmmeter.

5.Disconnect plugs J6 from the G3521 control board and J9 from the M19248 snubber PC board. This electrically isolates the SCR bridge assembly. See Figure F.6.

Return to Section TOC

Return to Master TOC

POWER MIG 255

Page 62
Image 62
Lincoln Electric SVM144-B service manual Active SCR Rectifier Assembly Test