TOC

F-17

TROUBLESHOOTING & REPAIR

F-17

RECTIFIER DIODE BRIDGE TESTING (continued)

Return to Section

Return to Section TOC

Return to Section TOC

Return to Master

Return to Master TOC

Return to Master TOC

6.Turn the POWER MIG 255 ON/OFF POWER SWITCH to ON.

7.Carefully make the following voltage tests:

a.Turn the machine OFF between each test.

b.Carefully connect the meter plugs to the exposed lead connections.

c.Turn the machine ON to conduct the voltage test.

FROM

TO

EXPECTED

LEAD

LEAD

VOLTAGE

 

 

 

208R

206

28 VAC

209R

206

28 VAC

 

 

 

8.If any of the AC voltages tested are incorrect or missing, check the M19248 snubber PC board and associated leads and connections. See the wiring diagram.

9. Make the following voltage test:

a. Turn the machine OFF between each test.

b. Carefully connect the meter probes to the exposed lead connections.

c. Turn the machine ON to conduct the voltage test.

FROM

TO

EXPECTED

LEAD

LEAD

VOLTAGE

 

 

 

354

206

36 VDC

 

 

 

10. If the DC voltage tested is incorrect or missing, and the AC voltages are cor- rect, the rectifier diode bridge may be faulty.

Return to Section TOC

Return to Master TOC

POWER MIG 255

Page 55
Image 55
Lincoln Electric SVM144-B service manual 208R 206 28 VAC 209R