F-49

TROUBLESHOOTING & REPAIR

F-49

CAPACITOR BANK

REMOVAL AND REPLACEMENT PROCEDURE

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and pre- cautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to per- form the test / repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

WARNING

The liquid electrolite in the capacitors is toxic. Do not touch the capacitors with any part of your body.

-------------------------------------------------------------------------------------------------------------------

DESCRIPTION

This procedure will aid the technician in the removal and replacement of the Capacitor Bank.

MATERIALS NEEDED

5/16 in. Nutdriver 3/8 in. Nutdriver

1/2 in. Open end wrench 3/8 in. Open end wrench Wiring diagram

POWER MIG 255

Page 87
Image 87
Lincoln Electric SVM144-B service manual Capacitor Bank Removal and Replacement Procedure