to Section TOC

to Master TOC

F-12

TROUBLESHOOTING & REPAIR

F-12

MAIN TRANSFORMER TEST (continued)

FIGURE F.1 — G3521 CONTROL PC BOARD AND M19248 SNUBBER PC BOARD

MAIN TRANSFORMER TEST POINTS.

Return

Return to Section TOC

Return

Return to Master TOC

J6

X9 (8J5)

J5

#206

(3J5)

J3

J8

J1

X5

(6J6)

X6

(5J6)

X7

(4J6)

X8

(16J5)

#209S

(6J9)

J9

#208S

(2J9)

J4

J2

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

TEST PROCEDURE

WARNING

The ON/OFF POWER SWITCH will be “hot” during these tests.

----------------------------------------------------------

NOTE: Secondary voltages will vary pro- portionately with the primary input voltage.

1.Disconnect the main input power sup- ply to the machine.

2.Remove the case top and side panels with a 3/8 in. nutdriver.

3.Remove the tool tray with a 5/16 in. nut- driver.

4.Locate plug J5 and plug J6 on the G3521 control PC board, and J9 on the M19248 snubber PC board. See Figure F.1.

NOTE: The location of plugs may vary depending on the machine code.

5.Locate the following leads on plug J6 on the G3521 control PC board:

 

PLUG

LEAD

LOCATION

 

 

X5

6J6

X6

5J6

X7

4J6

 

 

POWER MIG 255

Page 50
Image 50
Lincoln Electric SVM144-B service manual Main Transformer Test, Test Procedure