TEST PROCEDURE

1.Disconnect main AC input power to the machine.

2.Remove the case top and side panels with a 3/8 in. nutdriver.

3.Remove the tool tray with a 5/16 in. nut- driver.

4.Verify that the capacitors have completely discharged with a volt- ohmmeter.

5.Disconnect plugs J6 from the G3521 control board and J9 from the M19248 snubber PC board. This electrically isolates the SCR bridge assembly. See Figure F.3.