Lincoln Electric SVM144-B service manual Rectifier Diode Bridge Testing

Models: SVM144-B

1 108
Download 108 pages 13.35 Kb
Page 54
Image 54

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-16

TROUBLESHOOTING & REPAIR

F-16

RECTIFIER DIODE BRIDGE TESTING (continued)

FIGURE F.2 — G3521 RECTIFIER DIODE BRIDGE LOCATION.

RECTIFIER

DIODE BRIDGE

(D2)

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

TEST PROCEDURE

1.Disconnect the main AC input power to the machine.

2.Remove the case top and side panels with a 3/8 in. nutdriver.

3.Perform the Main Transformer Test to ensure the proper voltages are supplied to the M19248 snubber PC board.

4.Locate the following leads:

LEAD

208R

209R

354

206

Leads #208R, #209R, and #354 are connected to the rectifier diode bridge (D2). See Figure F.2. Lead #206 is connected at the output shunt. See the wiring diagram.

5.Connect main input power to the machine.

POWER MIG 255

Page 54
Image 54
Lincoln Electric SVM144-B service manual Rectifier Diode Bridge Testing