OPERATION

B-3

 

 

 

RANGE” SWITCH

The “Range” switch is used to select one of three amperage ranges with generous overlap for Stick/TIG welding, or one Wire Feed welding range.

Process

Range Setting

Current Range

STICK/TIG

90 Max.

40 to 90 Amps

(constant current)

145 Max.

70 to 145 Amps

(3 range settings)

210DC/225AC Max.

120 to 210 (DC) 225(AC)

WIRE FEED

15 to 25V

Up to 200 Amps

(constant voltage)

(one range setting)

 

 

 

 

 

 

 

 

CAUTION

 

 

Never change the “RANGE” Switch setting while

 

 

welding. This will damage the switch.

 

------------------------------------------------------------------------

 

 

 

CONTROL” DIAL

 

 

Provides a fine welding current adjustment within the

 

 

Range Switch settings in the STICK mode and welding

 

 

voltage control with the Range switch set in the wire

 

 

feed mode.

 

 

 

 

 

POLARITY SWITCH

 

 

 

 

 

Provides three selectable welding polarities: AC, DC+ & DC- .

 

 

 

 

CAUTION

 

 

 

 

Never change the Polarity switch setting while welding.

 

 

 

This will damage the switch.

 

-------------------------------------------------------------------------------------------------------------------

RANGER® 10,000 AND RANGER® 10,000 PLUS APPROXIMATE FUEL CONSUMPTION

 

 

 

 

 

 

 

 

 

KOHLER

 

HONDA

 

ROBIN / SUBARU

 

20 H.P. COMMAND

 

20 H.P. GX620KI

 

20.5 H.P. P220

 

 

23 HP CH23S

 

 

 

 

22.5 HP EH665

Low Idle - No Load

 

.4 Gallons/Hour

 

.3 Gallons/Hour

 

.6 Gallons/Hour

2200 RPM

 

(1.5 Liters/Hour)

 

(1.3 Liters/Hour)

 

(2.3 Liters/Hour)

High Idle - No Load

 

.7 Gallons/Hour

 

.7 Gallons/Hour

 

.8 Gallons/Hour

3700 RPM

 

(2.8 Liters/Hour)

 

(2.8 Liters/Hour)

 

(3.0 Liters/Hour)

AC CC Weld Output

 

1.2 Gallons/Hour

 

1.3 Gallons/Hour

 

1.5 Gallons/Hour

225 Amps @ 25 Volts

 

(4.6 Liters/Hour)

 

(5 Liters/Hour)

 

(5.8 Liters/Hour)

DC CC Weld Output

 

1.3 Gallons/Hour

 

1.5 Gallons/Hour

 

1.6 Gallons/Hour

210 Amps @ 25 Volts

 

(4.9 Liters/Hour)

 

(5.9 Liters/Hour)

 

(6.1 Liters/Hour)

DC CV Weld Output

 

1.2 Gallons/Hour

 

1.2 Gallons/Hour

 

1.2 Gallons/Hour

200 Amps @ 20 Volts

 

(4.5 Liters/Hour)

 

(4.5 Liters/Hour)

 

(4.5 Liters/Hour)

Auxiliary Power

 

1.4 Gallons/Hour)

 

1.7 Gallons/Hour)

 

1.6 Gallons/Hour)

9000 Watts

 

(5.3 Liters/Hour)

 

(6.5 Liters/Hour)

 

(6.1 Liters/Hour)