F-5

TROUBLESHOOTING & REPAIR

F-5

 

 

 

 

 

 

TROUBLESHOOTING GUIDE

 

 

 

 

Observe Safety Guidelines

 

 

 

 

 

detailed in the beginning of this manual.

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

No weld output, the auxiliary

1.

Check the open circuit voltage

1. Disconnect lead W1 from the

power (230-115VAC) is operating

 

(OCV) at the welder output ter-

Output Bridge (D1) and check

normally. Engine runs normally.

 

minals, engine at high idle (3650

for the presence of 80VAC from

 

 

 

RPM). Normal maximum is 73

lead W1 to lead W2 on the main

 

 

 

to 80VAC.

Normal DC maxi-

stator winding. See wiring dia-

 

 

 

mum is 67 to 72VDC.

If the

gram. If the AC voltage is NOT

 

 

 

OCV is OK then proceed to

present, the winding in the sta-

 

 

 

Step #2. If the OCV is not pre-

tor may be faulty.

Check the

 

 

 

sent at the welder output termi-

winding for continuity and test

 

 

 

nals, contact your local Lincoln

to be sure it is NOT grounded to

 

 

 

Authorized

Field

Service

the stator iron. Replace if nec-

 

 

 

Facility.

 

 

essary. If the correct AC volt-

 

 

2.

Check the

welding

cables,

age is present, proceed to step

 

 

#2.

 

 

 

 

clamps and electrode holder for

 

 

 

 

 

 

 

 

 

loose or broken connections.

2. Check the Reactor, Range

 

 

 

 

 

 

Switch (S1) and

associated

 

 

 

 

 

 

wires for loose or faulty connec-

 

 

 

 

 

 

tions. Check the reactor wind-

 

 

 

 

 

 

ing for continuity and test to be

 

 

 

 

 

 

sure it is NOT grounded to the

 

 

 

 

 

 

reactor iron.

 

 

 

 

 

 

 

3. Check the Choke (L1), Polarity

 

 

 

 

 

 

Switch (S2) and

associated

 

 

 

 

 

 

wires for loose or faulty connec-

 

 

 

 

 

 

tions. Check the choke winding

 

 

 

 

 

 

for continuity and test to be

 

 

 

 

 

 

sure it is NOT grounded to the

 

 

 

 

 

 

choke iron.

 

 

 

 

 

 

 

4. Check the weld output termi-

 

 

 

 

 

 

nals and associated wires for

 

 

 

 

 

 

loose or faulty connections.

 

 

 

 

 

 

5. Perform the Output Bridge

 

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.