Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-39

TROUBLESHOOTING & REPAIR

F-39

 

 

 

NORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM (CV MODE)

HIGH IDLE - NO LOAD - OUTPUT CONTROL AT MAXIMUM

CH1

0 volts

20 volts

5 ms

This is the typical CV output voltage generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER® 10,000 & RANGER® 10,000 PLUS

Page 79
Image 79
Lincoln Electric SVM168-B Normal Open Circuit Weld Voltage Waveform CV Mode, High Idle no Load Output Control AT Maximum