F-8

TROUBLESHOOTING & REPAIR

F-8

 

 

 

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

No DC welding output. AC welding

1. Make sure the Polarity Switch is

1. Perform the Output Bridge Test.

output and auxiliary power is nor-

in the proper position and is

2.

Check the Choke (L1),

the

mal.

 

“seated” correctly.

 

 

Polarity Switch (S2) and associ-

 

 

 

 

 

 

2. Make sure the electrode and

 

ated wires for loose or faulty

 

 

polarity are correct for the

 

connections. Check the choke

 

 

process being used.

 

winding for continuity and test

 

 

 

 

to be sure it is NOT grounded

 

 

 

 

the choke iron.

 

 

 

 

No AC welding output. DC welding

1. Make sure the Polarity Switch is

1. Check the operation of the

output and auxiliary power is nor-

in the proper position and is

 

Polarity Switch (S2). Also check

mal.

 

“seated” correctly.

 

the associated wires for loose

 

 

2. Make sure the electrode is cor-

 

or faulty connections.

See

 

 

 

Wiring Diagram.

 

 

 

rect for the process being used.

 

 

 

 

 

 

 

 

 

3. Make sure the welding cables

2.

Check for continuity from lead

 

 

 

“S2” to lead “E” located in the

 

 

are not coiled or too long.

 

 

 

 

main stator. See Wiring Dia-

 

 

 

 

 

 

 

 

gram.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

RANGER® 10,000 & RANGER® 10,000 PLUS

Page 48
Image 48
Lincoln Electric SVM168-B service manual Troubleshooting Guide