F-35

 

 

 

TYPICAL DC WELD OUTPUT WAVEFORM (CC MODE)

MACHINE LOADED

CH1

0 volts

20 volts

5 ms

MACHINE LOADED TO 200 AMPS AT 26 VDC

This is the typical DC output voltage generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 5 milliseconds in time. The machine was loaded with a resistance grid bank.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER® 10,000 & RANGER® 10,000 PLUS