F-6

TROUBLESHOOTING & REPAIR

F-6

 

 

 

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

No auxiliary power, welding output

1. If machine is equipped with cir-

1. Check the

auxiliary power

is normal. Engine runs normally.

cuit breakers, check circuit

receptacles

and associated

 

 

breakers CB1 thru CB5. Reset

wires for loose or faulty connec-

 

 

if tripped.

tions.

 

 

 

2. Make sure the Output Control

2. Perform the Auxiliary and

 

 

(R1) is set at the maximum

Field Winding Voltage Test.

 

 

position.

3. If machine is equipped with cir-

 

 

 

 

 

3. Check for loose or faulty plug(s)

cuit breakers, check for faulty

 

 

at the power receptacle(s).

breakers and loose or faulty

 

 

 

connections

on associated

 

 

 

wiring.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

RANGER® 10,000 & RANGER® 10,000 PLUS

Page 46
Image 46
Lincoln Electric SVM168-B service manual Field Winding Voltage Test