Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-33

TROUBLESHOOTING & REPAIR

F-33

 

 

 

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115 VAC SUPPLY)

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM

16.2 ms

CH1

0 volts

50 volts

5 ms

This is the typical AC output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine 115 VAC receptacle.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER® 10,000 & RANGER® 10,000 PLUS

Page 73
Image 73
Lincoln Electric SVM168-B Normal Open Circuit Voltage Waveform 115 VAC Supply, High Idle no Load Output Control AT Maximum