Lincoln Electric SVM168-B service manual Normal Open Circuit DC Weld Voltage Waveform CC Mode

Models: SVM168-B

1 112
Download 112 pages 575 b
Page 80
Image 80

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-40

TROUBLESHOOTING & REPAIR

F-40

 

 

 

NORMAL OPEN CIRCUIT DC WELD VOLTAGE WAVEFORM (CC MODE)

HIGH IDLE - NO LOAD - OUTPUT CONTROL AT MAXIMUM

CH1

0 volts

50 volts

5 ms

This is the typical DC output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER® 10,000 & RANGER® 10,000 PLUS

Page 80
Image 80
Lincoln Electric SVM168-B service manual Normal Open Circuit DC Weld Voltage Waveform CC Mode