F-9

TROUBLESHOOTING & REPAIR

F-9

 

 

 

TROUBLESHOOTING GUIDE

 

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

No constant voltage (CV) welding

1. Make sure the Range Switch

1. Check the operation of the

output. Constant current (CC) and

(S1) is in the proper position

Range Switch (S1) and check

the auxiliary power are operating

(CV) and “seated” correctly.

the associated wires for loose

normally.

 

2. Make sure the wire feeder is

or faulty connections.

See

 

 

Wiring Diagram.

 

 

 

connected correctly.

 

 

 

 

 

 

 

 

2. Check for continuity from lead

 

 

 

C1 to lead W1 located in the

 

 

 

main stator. See Wiring Dia-

 

 

 

gram.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.