Lincoln Electric SVM168-B service manual Abnormal Open Circuit DC Weld Voltage Waveform

Models: SVM168-B

1 112
Download 112 pages 575 b
Page 78
Image 78

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-38

TROUBLESHOOTING & REPAIR

F-38

 

 

 

ABNORMAL OPEN CIRCUIT DC WELD VOLTAGE WAVEFORM

HIGH IDLE - NO LOAD - OUTPUT CONTROL AT MAXIMUM

ONE OUTPUT DIODE NOT FUNCTIONING

CH1

0 volts

50 volts

5 ms

This is NOT the typical DC (+) output voltage waveform. One output diode is not functioning. Note the “gap” in the waveform. One output diode was disconnected to simulate an open or nonfunctioning output diode. Each vertical division represents 50 volts and each horizontal division repre- sents 5 milliseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER® 10,000 & RANGER® 10,000 PLUS

Page 78
Image 78
Lincoln Electric SVM168-B service manual Abnormal Open Circuit DC Weld Voltage Waveform