TROUBLESHOOTING AND REPAIR

F-16

 

FIELD DIODE BRIDGE TEST (continued)

FIGURE F.2 – DIODE BRIDGE CIRCUIT CONFIGURATION

POSITIVE DC

FIELD DIODE BRIDGE TEST (continued) +

+ FIGURE F.2 – DIODE BRIDGE CIRCUIT CONFIGURATIONPOSITIVE DC ~ +  ~

~

-

-

 

 

 

 

SINGLE PHASE BRIDGE

 

NEGATIVE DC
CIRCUIT CONFIGURATION

 

 

PROCEDURE

The diode bridge is configured as pictured above. The individual diodes can be tested using a diode tester or an ohm meter. The diodes will read open one way and shorted the other way. If any of the diodes read shorted or open in both directions, the diode bridge will need to be replaced.

BULLDOG® 140