PROBLEMS

(SYMPTOMS)

No auxiliary power - welding output is normal - engine runs normally.

POSSIBLE AREAS OF

MISADJUSTMENT(S)

OUTPUT PROBLEMS

1.Check circuit breakers CB1 and CB2. Reset if tripped.

2.Make sure that the control rheo- stat (R1) is set at “GENERATOR” (maximum).

3.Check for loose or faulty plug at power receptacle.

RECOMMENDED

COURSE OF ACTION

1.Check the auxiliary power re- ceptacles and associated wires for loose or faulty connections.

2.Check the continuity (zero ohms) of leads 3, 3A (black); 6, 6A (yellow); and 5 (white) from the receptacles to the stator windings. See the Wiring Dia- gram.

3.Make sure lead 5 (white) is grounded to the machine frame (zero ohms).

4.Check for an open or grounded auxiliary winding in the stator, 6 (yellow) to 3 (black). See the Wiring Diagram.