Lincoln Electric SVM208-A Troubleshooting And Repair, Problems Symptoms, Output Problems, Bulldog

Models: SVM208-A

1 101
Download 101 pages 8.56 Kb
Page 54
Image 54
PROBLEMS

F-6

TROUBLESHOOTING AND REPAIR

F-6

 

Observe Safety Guidelines detailed in the beginning of this manual.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

PROBLEMS

(SYMPTOMS)

No weld output - auxiliary power (230 - 115 VAC) operates normally - engine runs normally.

POSSIBLE AREAS OF

MISADJUSTMENT(S)

OUTPUT PROBLEMS

1.Check the open circuit voltage (OCV) at the welder output termi- nals. If OCV is okay, go to Step 2, below.

If OCV is not present at the welder output terminals, contact your local Lincoln Electric Authorized Field Service Facility.

2.Check the welding cables, clamps and electrode holder for loose or broken connections.

RECOMMENDED

COURSE OF ACTION

1.Check continuity (zero ohms) of lead W1A (black) from output terminal to reactor (L1). See the Wiring Diagram.

2.Check continuity (zero ohms) of lead W2 (black) from output ter- minal to stator winding. See the Wiring Diagram.

3.Check continuity (zero ohms) of lead W1 (black) from reactor (L1) to stator winding. See the Wiring Diagram.

4.Check reactor (L1) for continuity of winding. See the Wiring Dia- gram.

5.Check the stator for continuity of winding. See the Wiring Dia- gram.

6.Make certain the reactor and/or stator are NOT grounded. Mini- mum acceptable resistance to ground is 500 K-ohms.

Return to Section TOC

Return to Master TOC

POSSIBLE AREAS OFCAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

BULLDOG® 140

Page 54
Image 54
Lincoln Electric SVM208-A Troubleshooting And Repair, Return to Section TOC Return to Section TOC Return to Section TOC