TROUBLESHOOTING AND REPAIR

F-28

 

NORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM

HIGH IDLE – NO LOAD

CH1

0 volts

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

50 volts

5ms

This is the typical AC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 50 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

BULLDOG® 140