Installation

Location Requirements

To ensure successful operation of the DEFINITY Extender 1100 System, place the Switch Module within 500 feet (150 meters) of the DEFINITY ECS. The Switch Module may be mounted in any position or may be wall-mounted by using the optional wall-mount bracket. Install the module’s AC power adapter or power supply and cabling away from high-power/high-RF noise devices such as computers, fans, fluorescent ballasts, and power supplies.

Electrical Requirements

Use only the AC adapters provided with the DEFINITY Extender 1100 System. The Extender has been designed to operate from 120 VAC, 60 Hz.

!

CAUTION:

Do not apply power to the Switch Module until specifically instructed in the installation procedures.

NOTE:

Lucent Technologies strongly recommends that you supply both power and central office line surge protection for the PBX location and the remote location. Lucent Technologies recommends the 147C Line Surge Protector (#8310-006). Contact your Lucent Technologies representative for ordering instructions

3-2Issue 1 June 1998

Page 57