Troubleshooting

Table 4-3 shows the LED flashes that may occur on the Switch Module after the power-up LED sequence.

Table 4-3. Module LED Blink Sequence

LED

Meaning

Sequence

 

 

 

G

Module is online to a Remote Module; no

 

abnormalities have been detected.

GGModule is in COD (Call on Demand) waiting mode; no abnormalities have been detected.

GGGModule is idle and waiting for connect sequence; no abnormalities have been detected.

R

DSP is off-line. Try to power cycle the module. If

 

continues, contact the Helpline.

 

 

RR

Module is waiting for connection to DEFINITY

 

DCP port. (PHONE/SWITCH port on the

 

Extender is not connected) Check the

 

connection and that the distance between the

 

DEFINITY ECS port and the Switch Module is

 

within 500 ft.

RRRModem error. Try to power cycle the module. If it continues, contact the Helpline.

Y

Modem is trying to connect, or modem is

 

disconnecting. No abnormalities have been

 

detected.

4-6Issue 1 June 1998

Page 71
Image 71
Lucent Technologies 1100 manual Module is online to a Remote Module no