Lucent Technologies 1100 manual DIP Switch Configuration

Models: 1100

1 84
Download 84 pages 29.37 Kb
Page 60
Image 60

Installation

Following installation, administer the line and station ports that use the Switch Module according to the instructions in DEFINITY® Communications System Generic 3 Implementation Guide, Issue 1, document #555-230-655.

Follow these steps to install the Switch Module:

1.Ensure that the module has the proper DIP switch configuration (see Table 3-1).

Table 3-1. DIP Switch Configuration

Switch #

OFF

ON

 

 

 

1

μ-Law companding

A-Law companding

 

 

 

2

Normal operation

Reserved

 

 

 

3

Normal operation

Reserved

 

 

 

4

Normal operation

Test mode

 

 

 

NOTE:

You should not change the factory-set DP switches; all DIP switches be set at OFF. Check with your system administrator before making changes.

! CAUTION:

Do not plug the A/C adapters into the electrical outlets until instructed to do so in the following procedure.

Issue 1 June 1998 3-5

Page 60
Image 60
Lucent Technologies 1100 manual DIP Switch Configuration