Installation

!

CAUTION:

Connecting the Remote Module to the DEFINITY ECS can result in damage to the module. Prior to installation, check that you have the Switch Module by looking at the name on the top of the unit.

2.Connect the wiring of the DEFINITY analog circuit pack (the 8- port TN742 or the 16-port TN746) or a dedicated central office line (provided only with this connection) with the TELCO LINE jack of the Switch module at the on-premise location. See the DEFINITY® Communications System Generic 3, Installation for Single-Carrier Cabinets manual for complete instructions.

3.If you have not already done so while programming passwords, connect the Switch Module PHONE/SWITCH jack to the 2- wire, 24-port TN2224 circuit pack or 16-port TN2181 circuit pack on the DEFINITY ECS. See the DEFINITY® Communications System Generic 3, Installation for Single- Carrier Cabinets manual for complete instructions.

!

CAUTION:

Do not plug the line cord into the PHONE/SWITCH jack of the Switch Module. Damage to circuits may result.

4.Connect the AC adapter, provided with your system, to the Switch Module. Plug the adapter into a standard 120 VAC electrical outlet.