c. Fault - Signal clipping

c. Fault - Signal clipping

The above error message is displayed when the incoming signal is classified as too loud resulting in clipping (distortion).

An overly loud measuring signal results in this error message.

Solution:

Lower the measuring signal volume before continuing with the measurement.

A loud noise from the local environment that has corrupted the measurement results in this error message.

Solution:

Repeat the measurement with no changes; however refrain from making excessive noise when measuring.

Useful hint: You can exit a commenced measurement by clapping close to the microphone. This results in the above error message.

d. Fault - Low signal

The above error message is displayed when the measurement has taken more than 5 minutes for the low frequency signal or 2 minutes for the high frequency signal. This happens most often when using a low measuring signal compared to the background noise of your environment, something that results in prolonged measuring times.

Solution:

Raise the measuring signal volume before continuing with the measurement, or reduce the noisy elements in your environment.

35

Page 35
Image 35
Lyngdorf Audio TDA 2200 owner manual c. Fault - Signal clipping, d. Fault - Low signal