Air-Cooled Condenser Cleaning

Section 4

Maintenance

 

 

ICE CHUTE REMOVAL

RFS0300/RFS0650/RF1200/RF2300 Only

1.Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine.

2.Disconnect water supply.

3.Remove water reservoir cover.

4.Remove bin thermostat from ice chute.

5.Loosen bolts holding cross member.

6.Lift cross member and remove ice chute.

LOOSEN

TIP TOP OF ICE

SUPPORT BOLTS

CHUTE BACK AND

 

LIFT TO REMOVE

ICE CHUTE SWITCH ACTUATOR REMOVAL

RFS0300/RFS0650/RF1200/RF2300 Only

1.Pull to remove nylon end cap.

2.Slide pin to remove.

3.Remove both sections of the pressure switch bracket.

INCORRECT REASSEMBLY CAN

RESULT IN AN ICE MACHINE

THAT WILL NOT RUN

Air-Cooled Condenser Cleaning

!Warning

Disconnect electric power to the ice machine and the remote condenser at the electric service switch before cleaning the condenser.

A dirty condenser restricts airflow, resulting in excessively high operating temperatures and reduced ice production. Clean the condenser at least every six months.

!Caution

The condenser fins are sharp. Use care when cleaning them.

1.Clean the outside of the condenser with a soft brush or a vacuum with a brush attachment. Shine a flashlight through the condenser to check for dirt between the fins. If dirt remains, a method suitable to remove the contamination must be used to ensure air flow.

2.RFS0300/RFS0650/RF1200/RF2300 Only. Clean the washable filter with a mild soap and water solution.

Arctic Pure Water Filter System

Engineered specifically for Manitowoc ice machines. This water filter is an efficient, dependable, and affordable method of inhibiting scale formation, filtering sediment, and removing chlorine taste and odor.

Manitowoc Cleaner and Sanitizer

Manitowoc Ice Machine Nickel Safe Cleaner is available in convenient 16 oz. (473 ml) bottles. Manitowoc Ice Machine Sanitizer is available in 16 oz. (473 ml) and

1 gal (3.78 L) bottles.

Cleaner Part Number

Sanitizer Part Number

16 oz.

000000084

16 oz.

94-0565-3

 

 

1 Gallon

94-0581-3