Manitowoc Ice RF manual Installation Instructions, Section, Quietqube Remote Condensing Unit

Models: RF

1 54
Download 54 pages 30.34 Kb
Page 9
Image 9
QUIETQUBE REMOTE CONDENSING UNIT

Installation Instructions

Section 2

 

 

Maximum Breaker Size & Minimum Circuit Amperage Chart

Important

Due to continuous improvements, this information is for reference only.

Please refer to the ice machine serial number tag to verify electrical data.

Serial tag information overrides information listed on this page.

 

Voltage

 

Air-Cooled

 

Water-Cooled

QuietQube

Series Ice

Max

Min

Total

Max

Min

Max

Total

Phase

Fuse/

Fuse/

Fuse/

Machine

Circuit

Circuit

Circuit

Circuit

Cycle

Circuit

Circuit

Circuit

 

Amps

Amps

Amps

Amps

 

 

Breaker

Breaker

Breaker

 

 

 

 

 

 

RF0244

115/1/60

15 Amp

N/A

7.5

N/A

N/A

230/1/50

10 Amp

N/A

0.87

N/A

N/A

 

RF0266

115/1/60

15 Amp

N/A

7.5

N/A

N/A

230/1/50

10 Amp

N/A

0.87

N/A

N/A

 

RF0385

115/1/60

15 Amp

N/A

10.0

N/A

N/A

230/1/50

N/A

N/A

N/A

N/A

N/A

 

RF0388

115/1/60

15 Amp

N/A

10.0

N/A

N/A

230/1/50

10 Amp

N/A

2.9

N/A

N/A

 

RF0399

115/1/60

15 Amp

N/A

10.0

N/A

N/A

230/1/50

10 Amp

N/A

2.9

N/A

N/A

 

RF0644

115/1/60

25 Amp

N/A

13.5

N/A

N/A

RFS0300

115/1/60

20 Amp

12.8

N/A

N/A

N/A

RFS0650

115/60/1

25 Amp

16.3

N/A

25 Amp

15.4

208-230/1/60

15 Amp

8.7

N/A

15 Amp

8.2

 

RF1200

208-230/1/60

15 Amp

15.0

N/A

15 Amp

15.0

15 Amp

1.4

230/1/50

16 Amp

7.3

N/A

16 Amp

7.3

10 Amp

1.4

 

RF2300

208-230/3/60

20 Amp

15.0

N/A

20 Amp

15.0

15 Amp

3.2

400-415/3/50

16 Amp

13.9

N/A

16 Amp

13.9

10 Amp

3.2

 

RF1200R

208-230/1/60

15 Amp

1.4

N/A

N/A

N/A

RF2300R

208-230/3/60

15 Amp

3.2

N/A

N/A

N/A

Maximum allowable voltage variation at compressor start-up is ±10% of voltage listed above and on the model/serial plate.

QUIETQUBE REMOTE CONDENSING UNIT

Condensing Unit

Voltage Phase Cycle

Maximum Fuse/Circuit Breaker

Minimum Circuit Amps

 

208-230/60/1

15

15

RCU1075

208-230/60/3

15

15

 

208-230/50/1

15

15

 

208-230/60/1

15

15

RCU2375

208-230/60/3

15

15

 

208-230/50/1

15

15

9

Part Number 000007644 3/11

Page 9
Image 9
Manitowoc Ice RF manual Installation Instructions, Section, Quietqube Remote Condensing Unit