Additional Checks for QuietQube Models

Section 2

Installation Instructions

 

 

Additional Checks for QuietQube Models

Is the lineset length, rise and drop within the guidelines?

Are the suction and liquid line shut-off valves open?

Is the line set routed properly?

Are both refrigeration lines to remote condensing unit run so they do not lay in water and are properly insulated?

Does the condenser fan motor(s) operate properly after start-up?

Have all the refrigeration fittings and joints been leak checked?

Has the condenser/condensing unit been installed to prevent any roofing damage?

Have the refrigeration lines been insulated and secured properly to prevent vibration?

Has the RCU remote condensing unit been located where ambient temperatures will remain in the range of -20° to 120°F (-29° to 48.9°C)?

Is a refrigeration oil trap (S-trap) installed if the condenser is installed 21 to 35 feet (6 to 11 m) above the ice machine head?

Part Number 000007644 3/11

16