Section 2

Installation Instructions

 

 

Step 6 Leak Check The Refrigeration System

Leak check the new line set connections at the ice machine head section, condensing unit and S trap as well as all factory joints throughout the entire system. Disconnect power to the remote condensing unit. Place the rocker switch into the ON position. This allows the low side and high side pressures to equalize for leak checking. Place the rocker switch in the OFF position. Connect power to the remote condensing unit and allow system to pump down after leak checking is complete.

Step 7 Open The Valves Prior To Starting The Ice Machine

A.Slowly backseat (open-turn counterclockwise) the suction line shutoff valve.

B.Slowly backseat (open-turn counterclockwise) the liquid line shutoff valve.

Open suction and liquid line shut-off valves

Open Valves

Important

All refrigeration valve caps must be reinstalled to prevent future refrigeration leaks.

Verify O-ring in schrader valve caps are intact and reinstall on shutoff valves to prevent refrigerant leakage. Replace shutoff valve access caps and torque to the following specifications.

Torque Values

Stem

18-20 ft. lbs. (24.4-27.1 Nm)

 

 

Caps

12-15 ft. lbs. (16.3-20.3 Nm)

 

 

Schrader Core

1.5-3 in. lbs. (0.17-0.34 Nm)

 

 

Step 8 Insulation Requirements

To prevent condensation the entire suction line must be insulated. All insulation must be airtight and sealed at both ends.

The following insulation requirements prevent condensation at 90°F (32.2°C) ambient 90% Relative Humidity. If higher humidity is expected, increase insulation thickness.

The entire suction line set requires:

Suction Line

Liquid Line

Min. Insulation

Thickness

 

 

 

 

 

 

 

1/2 in. (13 mm)

5/8 in. (16 mm)

3/8 in. (10 mm)

Suction Line

1/4 in. (7 mm)

 

 

 

 

Liquid Line

 

 

 

Important

To prevent condensation the entire suction line must be insulated. All insulation must be airtight and sealed at both ends.

The minimum requirements are for conditions at or below 90% humidity and 90°F (32°C) ambient. When higher humidity will be experienced, or local code requires, insulation wall thickness will need to be increased.

Part Number 000007644 3/11

14

Page 14
Image 14
Manitowoc Ice RF manual Leak Check The Refrigeration System, Open The Valves Prior To Starting The Ice Machine, Open Valves

RF specifications

Manitowoc Ice RF is a leading series in the ice-making industry, renowned for its innovative technologies and commitment to efficiency. Designed to meet the high demands of commercial food service operations, the RF model features a range of cutting-edge attributes that set it apart from competitors.

One of the main features of Manitowoc Ice RF is its advanced refrigeration system. The machine employs an Adaptive Harvest Control technology that ensures consistent ice quality by continually monitoring the ice-making process and adjusting accordingly. This results in reliable production of clear, hard ice cubes without the usual inconsistencies found in other machines.

The Manitowoc Ice RF models are designed with energy efficiency in mind. They utilize high-efficiency compressors and optimized insulation methods, significantly reducing energy consumption compared to traditional ice machines. This not only contributes to cost savings for businesses but also aligns with environmentally conscious practices, helping to reduce the overall carbon footprint.

Another notable characteristic of the RF series is its streamlined design, which allows for easy installation and maintenance. The machines are compact, making them ideal for establishments with limited space. The removable panels and accessible components simplify routine cleaning and servicing, ensuring the unit operates at peak performance and extends its life cycle.

Food safety is another focus of the Manitowoc Ice RF series. The machines incorporate an internal, easy-to-clean design that minimizes the risk of contamination. The anti-microbial protection on key surfaces helps prevent the growth of harmful bacteria, ensuring that the ice produced is safe for consumption.

In addition to its robust construction and technology, Manitowoc Ice RF offers various production capacities, catering to different business needs. Whether in a bustling restaurant, a hotel, or a convenience store, there is a model that fits the required ice production volume.

Overall, the Manitowoc Ice RF series combines state-of-the-art technology, energy efficiency, and ease of use to provide an exceptional ice-making solution for commercial establishments. Its commitment to quality and innovation makes it a preferred choice for businesses aiming to enhance their food service operations while maintaining high standards of safety and efficiency.