The location must not obstruct airflow through or around the ice machine (condenser airflow is in and out the front). Refer to the chart below for clearance requirements.

INSTALLATION

LOCATION OF ICE MACHINE

The location selected for the ice machine must meet the following criteria. If any of these criteria are not met, select another location.

The location must be indoors.

The location must be free of airborne and other contaminants.

Air temperature: must be at least 50ºF (10ºC) but must not exceed 110ºF (43ºC).

The location must not be near heat-generating equipment or in direct sunlight.

The location must be capable of supporting the weight of the ice machine and a full bin of ice.

The location must allow enough clearance for water, drain, and electrical connections in the rear of the ice machine.

Top/Sides

Back

Self-Contained

Self-Contained

Air-Cooled

Water-Cooled

5" (127 mm)*

5" (127 mm)*

5" (127 mm)*

5" (127 mm)*

 

 

*NOTE: The ice machine may be built into a cabinet.

There is no minimum clearance requirement for the top or left and right sides of the ice machine. The listed values are recommended for efficient operation and servicing only.

CAUTION

The ice machine must be protected if it will be subjected to temperatures below 32 F (0 C). Failure caused by exposure to freezing temperatures is not covered by the warranty.

13

Page 13
Image 13
Manitowoc Ice STH003 manual Installation, Location of ICE Machine