TEMPERATURE/RESISTANCE CHART

As the temperature rises at the thermistor block, the resistance drops.

IMPORTANT

If the ohmmeter reads “OL,” check the scale setting on the meter before assuming the thermistor is bad.

SM50 Resistance Chart

Temperature of Thermistor

Resistance

°C

 

 

°F

 

K Ohms (x 1000)

15.6° - 21.1°

 

60° -

70°

15.31

- 11.88

21.1° - 26.7°

 

70° -

80°

11.88 - 9.29

26.7° - 32.2°

 

80° -

90°

9.29

- 7.33

32.2° - 37.8°

 

90° - 100°

7.33

- 5.82

37.8° - 43.3°

 

100° -

110°

5.82

- 4.66

43.3° - 48.9°

 

110° -

120°

4.66

- 3.75

48.9° - 54.4°

 

120° -

130°

3.75

- 3.05

54.4° - 60.0°

 

130° -

140°

3.05

- 2.49

60.0° - 65.6°

 

140° -

150°

2.49

- 2.04

65.6° - 71.1°

 

150° -

160°

2.04

- 1.68

71.1° - 76.7°

 

160° -

170°

1.68

- 1.40

76.7° - 82.2°

 

170° -

180°

1.40

- 1.17

82.2° - 87.8°

 

180° -

190°

1.17

- 0.98

87.8° - 93.3°

 

190° -

200°

0.98

- 0.82

93.3° - 98.9°

 

200° -

210°

0.82

- 0.70

100°

 

212°

0.73

- 0.62

(boiling

water bath)

 

 

104.4° - 110.0°

220° - 230°

0.59

- 0.51

110.0° - 115.6°

230° - 240°

0.51

- 0.43

115.6° - 121.1°

240° - 250°

0.43

- 0.37

121.1° - 126.7°

 

250° - 260°

0.37

- 0.33

60

Page 60
Image 60
Manitowoc Ice STH003 manual TEMPERATURE/RESISTANCE Chart, SM50 Resistance Chart