Manitowoc Ice STH003 manual Freeze Harvest Cycle Psig Beginning

Models: STH003

1 88
Download 88 pages 51.31 Kb
Page 47
Image 47

ANALYZING DISCHARGE PRESSURE

1.Determine the ice machine operating conditions:

Air temp. entering condenser

______

Air temp. around ice machine

______

Water temp. entering sump trough______

2.Refer to Cycle Times/24 Hour Ice Production/Refrigeration Pressure Chart for ice machine being checked.

Use the operating conditions determined in Step 1 to find the published normal discharge pressures.

Freeze Cycle ______

Harvest Cycle______

3.Perform an actual discharge pressure check.

 

Freeze

Harvest

 

Cycle PSIG

Cycle PSIG

 

 

 

Beginning

__________

__________

of Cycle

 

 

Middle of

__________

__________

Cycle

 

 

End of

__________

__________

Cycle

 

 

4.Compare the actual discharge pressure (Step 3) with the published discharge pressure (Step 2).

The discharge pressure is normal when the actual pressure falls within the published pressure range for the ice machine’s operating conditions. It is normal for the discharge pressure to be higher at the beginning of the freeze cycle (when load is greatest), then drop through out the freeze cycle.