SAFETY TIMERS

The control board has the following non- adjustable safety timers:

Initial cycle is 5 minutes longer than subsequent cycles.

The ice machine is locked into the freeze cycle for 10 minutes (15 minutes initial cycle) before a harvest cycle can be initiated.

The maximum freeze time is 120 minutes at which time the control board automatically initiates a harvest cycle (step 4).

The maximum harvest time is 5 minutes at which time the control board automatically start a freeze cycle

22

Page 22
Image 22
Manitowoc Ice STH003 manual Safety Timers