ADJUSTING CUBE WEIGHT

The cube weight can be increased from the factory setting by adjusting the finish time.

Additional finishing time check:

Press and hold the power button for 5 seconds.

Count the flashes on the Automatic Ice Making light. The light will flash once for each additional minute of freeze cycle time.

Adjusting Finishing Time

Adjust in 1-minute increments and allow the ice machine to run several freeze/harvest cycles, and then inspect the ice cubes. If a heavier cube weight is desired add another minute of freeze time and repeat the process.

Press and hold the power button.

Press and release the clean button once for each additional minute of freeze cycle time desired.

Five minutes is the maximum additional freeze time that can be added. Pressing the clean button 6 times will reset the finishing time to zero additional minutes.