SUCTION PRESSURE HIGH CHECKLIST Problem

Cause

Improper Installation

Refer to “Installation/Visual Inspection Checklist”

Discharge Pressure

Discharge pressure is too high, and is affecting suction pressure, refer to “Freeze Cycle Discharge Pressure High Checklist”

Improper Refrigerant Charge

Overcharged

Wrong type of refrigerant

Non Condensable in system

Other

Non-Manitowoc components in system

Hot gas valve leaking

Defective compressor

Water inlet valve leaking

SUCTION PRESSURE LOW CHECKLIST Problem

Cause

Improper Installation

Refer to “Installation/Visual Inspection Checklist”

Discharge Pressure

Discharge pressure is too low, and is affecting suction pressure, refer to “Freeze Cycle Discharge Pressure Low Checklist”

Improper Refrigerant Charge

Undercharged

Wrong type of refrigerant

Other

Non-Manitowoc components in system

Improper water supply over evaporator refer to “Water System Checklist”

Loss of heat transfer from tubing on back side of evaporator

Restricted/plugged liquid line drier

Restricted/plugged tubing in suction side of refrigeration system

NOTE: Do not limit your diagnosis to only the items listed in the checklists.