COMPONENT SPECIFICATIONS AND

CHECK PROCEDURES

MAIN FUSE

Function

The control board fuse stops ice machine operation if electrical components fail causing high amp draw.

Specifications

CM50

Volt

250

Amp

10

Check Procedure

WARNING

High (line) voltage is applied to the control board at all times. Removing the control board fuse or moving the toggle switch to OFF will not remove the power supplied to the control board.

1.If the bin switch light is on with the ice damper closed, the fuse is good.

WARNING

Disconnect electrical power to the entire ice machine before proceeding.

2.Remove the fuse. Check the resistance across the fuse with an ohmmeter.

Reading

Result

 

 

Open (OL)

Replace fuse

Closed (O)

Fuse is good