COMPONENT SPECIFICATIONS AND
CHECK PROCEDURES
MAIN FUSE
Function
The control board fuse stops ice machine operation if electrical components fail causing high amp draw.
Specifications
CM50
Volt
250
Amp
10
Check Procedure
WARNING
High (line) voltage is applied to the control board at all times. Removing the control board fuse or moving the toggle switch to OFF will not remove the power supplied to the control board.
1.If the bin switch light is on with the ice damper closed, the fuse is good.
WARNING
Disconnect electrical power to the entire ice machine before proceeding.
2.Remove the fuse. Check the resistance across the fuse with an ohmmeter.
Reading | Result |
|
|
Open (OL) | Replace fuse |
Closed (O) | Fuse is good |