MAX. 1300°F

(700°C)

SV3071

4.Apply heat to copper tubing first and move flame toward valve socket.

A.Heat copper tubing for approximately 10 to 15 seconds then direct the heat to the solenoid socket

B.Heat the solenoid socket for 2 to 5 seconds and apply silver solder to joint.

C.Do not attempt to fill solenoid flange with solder. Solder will draw into socket.

5.Install new liquid line drier.

6.Leak check joints by pressurizing system with 150- psig nitrogen.

7.Evacuate and re-charge system to nameplate charge.

8.Reinstall coil (using a twisting motion) and attach wiring.

SV3073

83

Page 83
Image 83
Manitowoc Ice STH003 manual MAX F 700C