Field | Description | |
|
| |
| Parameters Savable. This bit is only used with the MODE SENSE com- | |
PS | mand. A returned value of 1 indicates that the target is capable of saving the | |
page in a | ||
| ||
| MODE SELECT command. | |
|
| |
Number of Cylinders | The number of physical cylinders that hold host data. | |
|
| |
Number of Heads | The number of heads that can access host data. | |
|
| |
Starting Cylinder | The value in this field is the physical cylinder at | |
|
| |
Write | which write precompensation is to begin. The first cylinder number is 0. If | |
the starting cylinder is equal to the value in the Number of Cylinders field, | ||
Precompensation | ||
write precompensation is disabled. | ||
| ||
|
| |
Starting Cylinder | The value in this field is the physical cylinder at which write current is re- | |
Reduced Write | duced. The first cylinder number is 0. If the starting cylinder for reduced | |
Current | write current is equal to the value in the Number of Cylinders field, reduced | |
| write current is disabled. | |
Drive Step Rate | Applies to | |
|
| |
| This field indicates a two’s complement location where the drive positions | |
Landing Zone | the disk heads. A negative value indicates that the heads are positioned be- | |
low cylinder 0 by that number of cylinders. A positive value greater than the | ||
Cylinder | ||
number of cylinders indicates that the heads are positioned beyond the cyl- | ||
| ||
| inders used for data storage at the location specified. | |
|
| |
| Rotational Position Locking is used for spindle synchronization in storage | |
| arrays. The modes are: | |
| 00b – Disabled | |
RPL | 10b – Master | |
01b – Slave | ||
| 11b – Not supported | |
| RPL can be overridden if the Maxtor (Vendor) Special Function Control | |
| page Auto field value = 1. This drive does not support spindle synchroniza- | |
| tion. | |
| Rotational Offset indicates the amount of rotational offset that the drive | |
| uses when synchronized. The rotational offset is applied in the retarded di- | |
| rection (lagging the synchronized spindle master). The value in the field is | |
| determined by the following formula: | |
| Offset = 0 … 255 | |
| 256 | |
Rotational Offset | For example, a numerator of 128 indicates an offset of 1/2 revolution | |
| ||
| (180°). | |
| The valid parameter values are 0 to 255. | |
| The specified value may be rounded. Rotational offset is not used when the | |
| drive is configured as the | |
Medium Rotation Rate | The disk rotation speed in RPM. | |
|
|