Table 5-97Rigid Disk Geometry Page-Field Descriptions (Page 4)

Field

Description

 

 

 

Parameters Savable. This bit is only used with the MODE SENSE com-

PS

mand. A returned value of 1 indicates that the target is capable of saving the

page in a non-volatile, vendor-specific location. The bit is reserved with the

 

 

MODE SELECT command.

 

 

Number of Cylinders

The number of physical cylinders that hold host data.

 

 

Number of Heads

The number of heads that can access host data.

 

 

Starting Cylinder

The value in this field is the physical cylinder at

 

 

Write

which write precompensation is to begin. The first cylinder number is 0. If

the starting cylinder is equal to the value in the Number of Cylinders field,

Precompensation

write precompensation is disabled.

 

 

 

Starting Cylinder

The value in this field is the physical cylinder at which write current is re-

Reduced Write

duced. The first cylinder number is 0. If the starting cylinder for reduced

Current

write current is equal to the value in the Number of Cylinders field, reduced

 

write current is disabled.

Drive Step Rate

Applies to stepper-motor actuators. Not applicable.

 

 

 

This field indicates a two’s complement location where the drive positions

Landing Zone

the disk heads. A negative value indicates that the heads are positioned be-

low cylinder 0 by that number of cylinders. A positive value greater than the

Cylinder

number of cylinders indicates that the heads are positioned beyond the cyl-

 

 

inders used for data storage at the location specified.

 

 

 

Rotational Position Locking is used for spindle synchronization in storage

 

arrays. The modes are:

 

00b – Disabled

RPL

10b – Master

01b – Slave

 

11b – Not supported

 

RPL can be overridden if the Maxtor (Vendor) Special Function Control

 

page Auto field value = 1. This drive does not support spindle synchroniza-

 

tion.

 

Rotational Offset indicates the amount of rotational offset that the drive

 

uses when synchronized. The rotational offset is applied in the retarded di-

 

rection (lagging the synchronized spindle master). The value in the field is

 

determined by the following formula:

 

Offset = 0 … 255

 

256

Rotational Offset

For example, a numerator of 128 indicates an offset of 1/2 revolution

 

 

(180°).

 

The valid parameter values are 0 to 255.

 

The specified value may be rounded. Rotational offset is not used when the

 

drive is configured as the synchronized-spindle master.

Medium Rotation Rate

The disk rotation speed in RPM.

 

 