Sense

Sense

Sense

Meaning

Key

Code

Qualifier

 

 

 

 

 

0x04

0x40

0x80

Unknown HW problem

Hdwe Error

 

 

 

0x40

0x82

Hardware Bug Check (check Info field)

 

 

 

 

 

 

0x40

0x83

Failed HDA test.

 

 

 

 

 

0x40

0x84

Failed PCB test.

 

 

 

 

 

0x40

0x85

EDC check failed.

 

 

 

 

 

0x40

0x86

Controller FIFO over/underflow error.

 

 

 

 

 

0x40

0x88

DIAG: Drive failed to read servowriter serial number.

 

 

 

 

 

0x40

0x89

DIAG: Failed XOR test.

 

 

 

 

 

0x40

0x90

EDC Check Failed 0

 

 

 

 

 

0x40

0x91

EDC Check Failed 1

 

 

 

 

 

0x40

0x92

EDC Check Failed 2

 

 

 

 

 

0x40

0x93

EDC Check Failed3

 

 

 

 

 

0x40

0x8A

Servo restart failed after set RPM command

 

 

 

 

 

0x40

0x8C

LBA mismatch error

 

 

 

 

 

0x40

0x8D

ETM test failure, drive failed to spin

 

 

 

 

 

0x40

0x8E

Could not achieve target RPM

 

 

 

 

 

0x40

0xA0

Test did not complete

 

 

 

 

 

0x40

0xA1

Test completed successfully, but failed.

 

 

 

 

 

0x40

0xA2

Invalid parameter was received.

 

 

 

 

 

0x40

0xA3

Invalid data in servo record. Prevented algorithm from completing.

 

 

 

 

 

0x40

0xA4

Servo record did not complete

 

 

 

 

 

0x40

0xA5

Read seek failed

 

 

 

 

 

0x40

0xA6

Write seek failed

 

 

 

 

 

0x40

0xA7

Raw seek failed

 

 

 

 

 

0x40

0xA8

Servo Diagnostic Test running.

 

 

 

 

 

0x40

0xA9

Invalid 97/98 super cmd seq. Must send 97 before 98

 

 

 

 

 

0x40

0xAA

Super Command 97 already running

 

 

 

 

 

0x40

0xAB

Complex magnitude is zero

 

 

 

 

 

0x40

0xAC

Could not complete the low-level BCV write function

 

 

 

 

 

0x40

0xAD

Got a divide by zero error in complex divide.

 

 

 

 

 

0x40

0xAE

WGATE negated due to shock or bump during BCV write

 

 

 

 

 

0x40

0xAF

Servo Death occurred during a BVC write operation

 

 

 

 

 

0x40

0xB0

Seek command completion timeout occurred

 

 

 

 

 

0x40

0xB1

Read an impossibility high number of good BCVS on this

 

 

 

 

 

0x40

0xB2

No read passes resulted in enough test BCVs being read

 

 

 

 

 

0x40

0xB3

The last read pass for test BCVs was good but shouldn’t be

 

 

 

 

 

0x40

0xB4

DestinationLoc expected vs actual mismatch. servo death recovery

 

 

 

 

 

0x44

0x00

Logical assertion (firmware consistency check)

 

 

 

 

 

0x44

0x84

Insufficient buffer memory for operation

 

 

 

 

 

0x90

0x01

Serial Port Packet Receive Error

 

 

 

 

5-126 Maxtor Atlas 10K V