Sense | Sense | Sense | Meaning | |
Key | Code | Qualifier | ||
| ||||
|
|
|
| |
0x04 | 0x06 | 0x90 | Invalid CP18 on disk | |
Hdwe Error |
|
|
| |
0x06 | 0x91 | Invalid CP21 on disk | ||
| ||||
|
|
|
| |
| 0x06 | 0x92 | Invalid CP22 in NVR | |
|
|
|
| |
| 0x06 | 0x93 | Head polarity cal failed. | |
|
|
|
| |
| 0x06 | 0x94 | Svo: Invalid head polarity vector in CP23 | |
|
|
|
| |
| 0x06 | 0x95 | Seek 1 failure during servo writer erase band resync | |
|
|
|
| |
| 0x06 | 0x96 | Seek failure during ARCs Calibration | |
|
|
|
| |
| 0x06 | 0x97 | Seek failure during Pes Linearization | |
|
|
|
| |
| 0x06 | 0x98 | Error during Pes Lin bode measurement | |
|
|
|
| |
| 0x06 | 0x99 | Seek 2 failure during servo writer erase band resync | |
|
|
|
| |
| 0x06 | 0x9A | Seek failure during pes linearization table update | |
|
|
|
| |
| 0x06 | 0x9B | Motor speed error after turbo spin recovery | |
|
|
|
| |
| 0x06 | 0x9C | Electrical offset calibration returned an invalid value | |
|
|
|
| |
| 0x06 | 0x9D | Went servo dead during head polarity/coarse ATT cal. | |
|
|
|
| |
| 0x06 | 0x9E | Data consistency failure during PES Linearization | |
|
|
|
| |
| 0x06 | 0x9F | Couldn't find sync in the erase band & couldn't restart servo | |
|
|
|
| |
| 0x06 | 0xA0 | Went servo dead after completing a seek | |
|
|
|
| |
| 0x06 | 0xA1 | Successful sync not in the erase band | |
|
|
|
| |
| 0x06 | 0xA2 | ID GAMMA projected value out of range | |
|
|
|
| |
| 0x06 | 0xA3 | OD GAMMA calibration values out of range | |
|
|
|
| |
| 0x06 | 0xA4 | OD GAMMA projected value out of range | |
|
|
|
| |
| 0x06 | 0xA5 | Could not start estimator on printed media | |
|
|
|
| |
| 0x06 | 0xA6 | Too many spoke errors on printed | |
|
|
|
| |
| 0x06 | 0xA7 | Too many spoke errors on printed | |
|
|
|
| |
| 0x06 | 0xA8 | Too much variation in position at crash stop | |
|
|
|
| |
| 0x06 | 0xA9 | Unable to determine a unique index | |
|
|
|
| |
| 0x06 | 0xAA | Too much runout at the crash stop even with BCVs | |
|
|
|
| |
| 0x06 | 0xAB | Crash stop position too large or too small | |
|
|
|
| |
| 0x06 | 0xAC | Too much position runout at the crash stop | |
|
|
|
| |
| 0x06 | 0xAD | Milli plant mag out of range | |
|
|
|
| |
| 0x06 | 0xAE | Milli loop mag out of range | |
|
|
|
| |
| 0x06 | 0xAF | Seek error for gamma frequency | |
|
|
|
| |
| 0x06 | 0xB0 | Seek error for FF Gain | |
|
|
|
| |
| 0x06 | 0xB1 | Cant find good track | |
|
|
|
| |
| 0x06 | 0xB2 | Servo Busy too long | |
|
|
|
| |
| 0x09 | 0x00 | Track following error | |
|
|
|
| |
| 0x09 | 0x91 | Svo:TA | |
|
|
|
| |
| 0x09 | 0x92 | Svo:TA | |
|
|
|
| |
| 0x09 | 0x93 | Svo:Bad | |
|
|
|
| |
| 0x09 | 0x94 | Svo:Bad | |
|
|
|
| |
| 0x09 | 0x95 | Svo: Offtrack Prediction | |
|
|
|
|
Maxtor Atlas 10K V |