Table 5-49Initiator-Changeable Mode Pages

Page Code

Page NameFunctionSize In
Bytes

 

 

 

 

 

 

 

00h

Unit Attention Control Page

Unit Attention reporting (enables

4

or

 

 

disables)

 

 

Read-Write Error Recovery Page

Medium Access Error recovery

 

01h

and

12

 

reporting procedures for

 

 

 

 

 

READ and WRITE commands

 

 

 

 

 

02h

Disconnect-Reconnect Page

Bus behavior during data trans-

16

fers

 

 

 

 

07h1

 

Medium Access Error recovery

 

Verify Error Recovery Page

and reporting procedures for the

12

 

 

VERIFY command

 

08h1

Caching Page

Cache policy

20

0Ah1

Control Mode Page

Command processing policy

12

0Ch

Notch and Partition Page

Drive geometry

24

reporting

 

 

 

19h

Port Control Page

Defines port control parameters

8

 

 

 

 

19h(1h)

Margin Control

Margin control values

16

 

 

 

 

19h(2h)

Saved Training

Saved training

234

Configuration

configuration values

 

 

19h(3h)

Negotiated Settings

Negotiated settings for current

14

I_T Nexus

 

 

 

19h(4h)

Report Transfer

Transfer capabilities

14

Capabilities

 

 

 

1Ah

Power Condition Page

Enable and set time intervals for

12

Idle and Standby modes

 

 

 

 

Information Exceptions Control Page

Defines methods to control re-

 

1Ch1

and operations of specific information-

12

al exception

porting

 

conditions.

 

 

NOTE:

1. This page is not supported by the SCSI-1/CCS Operating Mode.

Maxtor Atlas 10K V