Wall Oven and Cooktop Combination Installation Specifications

Installer

NOTE: Save these instructions for local electrical inspectors use.

Leave these instructions and other literature with consumer for future reference.

Installations specified in these instructions are approved for the AKT3000, AK2T30, AK2T36, AK2H30, AK2H36, AKR3000 cooktops, and AKED3060, AKES3060 downdraft cooktops, above AOCS3040 and AOES3030 Amana wall ovens. Stacked and side-by-side wall oven installation applies to Amana AOCS3040 and AOES3030 wall ovens only.

For additional individual unit requirements and clearances refer to the installation instructions packaged with the wall oven and cooktop.

All installations specified are for a 36" cabinet height, 23 1/2" minimum depth, and 3 1/4 x 10" venting.

!WARNING

To avoid property damage or personal injury, information in these installation specifications must be followed exactly.

Listed by Underwriter's Laboratories

AKED3060 or AKES3060 Downdraft Cooktop above AOES3030 or AOCS3040 Wall Oven

Junction box location and 10 1/8 x 3 3/8 inch vent location indicated in black.

A — 6 inches

B— 4 1/2 inches (from top of countertop)

C— 24 inches

D— 4 3/8 inches from top of countertop to top of vent cutout

H— 28 1/2 inch wall oven cutout width

I— 27 1/4 inch wall oven cutout height

J— 28 7/8 inch cooktop cutout width

K— 20 5/8 inch cooktop cutout depth

L— 4 1/2 inches from top of countertop to top of wall oven cutout

 

Centerline of cabinet

 

cutout

 

Oven and Cooktop

 

junction box

 

installed in

 

adjacent cabinet

 

C

 

C

 

C

 

K

L

J

 

I

 

H

A—4

16021875 Rev. 0

©2003 Maytag Appliances Company

Page 24