Component Testing Information
!WARNING
To avoid risk of electrical shook, personal injury or death: disconnect power to oven before servicing, unless testing requires it.
Illustration | Component | Test Procedure | Results | |
|
| Oven light socket | Test continuity of receptacle terminals. | Indicates continuity with bulb screwed in. |
|
|
| Measure voltage at oven light. | 120 VAC, see wiring diagram for terminal |
|
|
|
| identification. |
|
|
|
| If no voltage is present at oven light |
|
|
|
| check wiring. |
|
| Bake element | Test continuity of terminals. | Indicates continuity. |
|
|
| Test voltage to terminals. | 240 VAC |
|
| Broil element | Test continuity of terminals. | Indicates continuity. |
|
|
| Test voltage to terminals. | 240 VAC |
|
| Convection element | Test continuity of terminals. | Indicates continuity. |
|
|
| Test voltage to terminals. | 240 VAC |
|
| Convection motor fan | Verify supply voltage. | 120 VAC |
|
|
| Check continuity of terminals, and | Continuity |
|
|
| verify terminals are not shorted to | Convection fan will stay ON, when |
|
|
| chassis. | |
|
|
|
| oven door is opened. |
|
| Blower motor | Verify supply voltage. | 120 VAC |
|
|
| Check continuity of terminals, and | Continuity |
|
|
| verify terminals are not shorted to |
|
|
|
| chassis. |
|
|
| Heraeus sensor | Measure resistance. | Approximately 1100 at room |
|
|
|
| temperature 75ºF. |
|
| Hinge | Carefully open the hinge fully, and |
|
|
|
| insert a wooden dowel or screwdriver | ! CAUTION |
Opening |
| bit into opening. | Do not place hands in hinge area when | |
| Remove top and bottom screws | |||
| oven door is removed. Hinge can snap | |||
|
|
| securing hinge. | |
|
|
| closed and pinch hands or fingers. | |
|
|
| Slide hinge top towards rear of unit | |
|
|
| ||
|
|
| and guide hinge out through frame | |
|
|
| opening or storage drawer. | |
|
| Door lock switch | Switch connection in following | |
|
|
| positions: | |
| NC |
| Unlocked | |
| NO |
| Locked |
|
| COM |
|
|
|
|
| Controls | Verify proper operation. |
|
|
|
| Open at 115°F, Closes at 155°F | |
|
|
| Open at 260°F, Closes at 220°F | |
|
| Door plunger switch | Remove switch from unit and measure |
|
|
|
| the following points: |
|
|
|
| Plunger in infinite, Plunger out continuity. | |
C | NC |
| C NO | Plunger in continuity, Plunger out infinite. |
| NO |
|
|
|
10 | 16021875 Rev. 0 | ©2003 Maytag Appliances Company |