Maytag AOES3030, AOCS3040 manual Component Testing Information, 16021875 Rev, Opening

Models: AOCS3040 AOES3030

1 47
Download 47 pages 54.38 Kb
Page 10
Image 10
Component Testing Information

Component Testing Information

!WARNING

To avoid risk of electrical shook, personal injury or death: disconnect power to oven before servicing, unless testing requires it.

Illustration

Component

Test Procedure

Results

 

 

Oven light socket

Test continuity of receptacle terminals.

Indicates continuity with bulb screwed in.

 

 

 

Measure voltage at oven light.

120 VAC, see wiring diagram for terminal

 

 

 

 

identification.

 

 

 

 

If no voltage is present at oven light

 

 

 

 

check wiring.

 

 

Bake element

Test continuity of terminals.

Indicates continuity.

 

 

 

Test voltage to terminals.

240 VAC

 

 

Broil element

Test continuity of terminals.

Indicates continuity.

 

 

 

Test voltage to terminals.

240 VAC

 

 

Convection element

Test continuity of terminals.

Indicates continuity.

 

 

 

Test voltage to terminals.

240 VAC

 

 

Convection motor fan

Verify supply voltage.

120 VAC

 

 

 

Check continuity of terminals, and

Continuity

 

 

 

verify terminals are not shorted to

Convection fan will stay ON, when

 

 

 

chassis.

 

 

 

 

oven door is opened.

 

 

Blower motor

Verify supply voltage.

120 VAC

 

 

 

Check continuity of terminals, and

Continuity

 

 

 

verify terminals are not shorted to

 

 

 

 

chassis.

 

 

 

Heraeus sensor

Measure resistance.

Approximately 1100 at room

 

 

 

 

temperature 75ºF.

 

 

Hinge

Carefully open the hinge fully, and

 

 

 

 

insert a wooden dowel or screwdriver

! CAUTION

Opening

 

bit into opening.

Do not place hands in hinge area when

 

Remove top and bottom screws

 

oven door is removed. Hinge can snap

 

 

 

securing hinge.

 

 

 

closed and pinch hands or fingers.

 

 

 

Slide hinge top towards rear of unit

 

 

 

COM-NO=Open, COM-NC=Closed

 

 

 

and guide hinge out through frame

 

 

 

opening or storage drawer.

 

 

Door lock switch

Switch connection in following

 

 

 

positions:

 

NC

 

Unlocked

COM-NO=Closed, COM-NC=Open

 

NO

 

Locked

 

 

COM

 

 

 

 

 

Controls

Verify proper operation.

 

 

 

 

31–308417–02–0 Fan control

Open at 115°F, Closes at 155°F

 

 

 

31–31751801–0 Control limit

Open at 260°F, Closes at 220°F

 

 

Door plunger switch

Remove switch from unit and measure

 

 

 

 

the following points:

 

 

 

 

C-NC

Plunger in infinite, Plunger out continuity.

C

NC

 

C NO

Plunger in continuity, Plunger out infinite.

 

NO

 

 

 

10

16021875 Rev. 0

©2003 Maytag Appliances Company

Page 10
Image 10
Maytag AOES3030, AOCS3040 manual Component Testing Information, 16021875 Rev, Opening