![Auto Latch Motor](/images/new-backgrounds/62965/6296529x1.webp)
Testing Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to unit before servicing.
Auto Latch Motor
Do not remove latch motor from latch assembly. If latch motor is defective, replace latch assembly.
1.Disconnect power.
2.Slide oven out from wall cutout approximately 6 inches to gain access to control panel screws.
3.Remove screws securing control panel to unit, and pull control panel out of unit to gain access to latch assembly.
4.Disconnect lead wires from latch motor.
5.Connect jumper cord leads to latch motor.
6.Connect jumper cord to 110 AC power source.
7.Replace if latch motor fails to operate.
8.Reverse procedure to reconnect.
Convection Fan Motor
1.Turn off power to oven.
2.Remove oven from wall cutout.
3.Remove access fan plate to gain access to convection fan motor.
4.Disconnect wires from motor terminal connectors.
5.Attach ohmmeter leads to terminal tabs on motor.
6.A resistance reading of
Door Latch Assembly
Auto Latch Switches
Both unlock and lock door latch switches may be replaced.
1.Perform steps 1 through 3, from “Auto Latch Motor”.
2.Disconnect lead wires from door latch switch (unlock).
3.Set ohmmeter to the RX1 scale.
4.Attach meter leads to door latch switch (unlock).
5.Depress actuator arm. The meter should read continuity.
6.Reverse procedure to reconnect.
7.Use the same procedure to test the door latch switch (lock).
L1 L2 COM NO COM NO
| M |
|
|
|
| |
|
|
|
|
| Unlock | |
120 VAC | Lock | |||||
Switch | Switch | |||||
Motor | ||||||
S.P.N.O. | S.P.N.O. | |||||
|
|
|
Convection Element Testing
1.Disconnect power to oven.
2.Remove screws securing oven door to hinges and remove door.
3.Remove screws securing fan cover to gain access to convection element.
4.Remove screws securing convection element, and pull gentally outward to gain access to wire terminals.
5.Remove wire connector from element.
6.Attach ohmmeter leads to each of the element terminals. Set ohmmeter to RX1 or RX10 scale.
7.Low ohms or continuity should be indicated.
Broil Element Testing
1.Disconnect power to oven.
2.Remove screws securing oven door to hinges and remove door.
3.Remove screws securing broil element reflector.
4.Gentally pull downward and out to gain access to wire terminals.
5.Remove wire connector from element.
6.Attach ohmmeter leads to each of the element terminals. Set ohmmeter to RX1 or RX10 scale.
7.Low ohms or continuity should be indicated.
Bake Element Testing
1.Disconnect power.
2.Remove oven from wall cutout.
3.Remove screws securing element panel.
4.Remove screws securing element access plate.
5.Remove wire connector from element.
6.Attach ohmmeter leads to each of the element terminals. Set ohmmeter to RX1 or RX10 scale.
7.Low ohms or continuity should be indicated.
Double Switch
©2003 Maytag Appliances Company | 16021875 Rev. 0 | 15 |