Troubleshooting Procedures

!W ARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing requires power.

Single Dryer Troubleshooting Guide

No

Response

Is the display blank?

To Coin 1 or

Coin 2

Yes

See "Blank

Display " section.

 

 

 

Enter service mode using using

 

No

 

 

service switch. Does display

 

 

 

 

 

 

contain a diagnostic code?

 

 

 

 

 

 

Is the coin slide option

selected?

No

 

 

 

See diagnostic

Yes

 

 

 

 

code guide

 

 

 

 

 

 

 

Timings for the coin slide mode will cause coins to

not be counted . Deselect the coin slide

mode.

 

 

 

 

 

 

Coins are ignored if in

Is debit only mode

 

 

 

 

debit only mode. Select

 

Yes

 

 

selected?

 

 

 

the coin and debit or coin

 

 

 

 

 

 

 

 

 

 

 

 

 

 

only mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

Is price suppression

selected?

No

Drop a coin through the coin 1 (or coin 2) drop. does the "*" in the display flash?

No

 

 

 

The price and amount

 

 

 

remaining to be added

Yes

 

 

 

 

do not display in price

 

 

 

 

 

 

 

 

 

suppression mode.

 

 

 

 

 

 

 

Go to the section

Yes

 

 

"Abnormal Display

 

 

 

 

Or Function"

 

 

 

 

 

 

 

Check the coin mechanism for proper adjustment.

Check wiring and termination

between coin 1 (or coin 2) drop and the control board.

Unplug dryer and the

coin 1 connector

If the problem still exists, replace the optic sensor.

If the problem still exists, replace the control board.

No

Clean the optic

sensor, if necessary

Is the resistance

between the red wire and the white wire in the coin 1 connector greater than 10K ohms?

No

Make sure that there is not too much ambient light. If problem still exists, replace the coin1 (or coin 2) optic sensor.